HOME > Products > Ultraviolet Irradiation Equipment UVB-300/850/1800

ISO9001:2000 certification

ISO9001:2000

Ultraviolet Irradiation Equipment UVB-300/850/1800

Compact designed main housing is including UV light source, reflection, shutter and power controller.
You can irradiate UV ray to your small points by the condensing lens through the quartz or liquid optical fibers.

 

Major applications

  • Fix of parts of chip
  • Adhesive of LD optical disk
  • Adhesive of Parts of optical pick-up
  • Fix of bundled coil
  • Adhesive of magnetic heads,glases and lens
  • Stiffening of fibers
  • Stop up corner of liquid crystal display plate
 

Features

Remote function Possible shutter, light intensity control, and lamp ON/OFF operation from outside.
Light intensity control Possible light intensity control continuously using the integrated iris plate.
Employed highrate condensing lens Affliated both 850W and 1800W realized high irradiation.
Employed preset lamp method
(*Only for UVB-300)
Position adjustment after replacing the lamps is not required as the device employs a lamp and oval mirror in one body, and easy to replace the lamp for maintenance.
 

Structure

  • Main housing
  • Fiber
  • Lens
 

Irradiation example

Irradiation example
 

Photo

UBV-300UVB-850/1800

Specifications

UVB-300

Input power voltage 100 VAC, 50/60 Hz
Power consumption 330 W
Lamp model name HTM300IF
Lamp life 2000 hours (standard value)
Light intensity (initial value) *5000 mW/cm2 (standard value)
Irradiation strength 100mm square 50mW/cm2   10mm square 5000mw/cm2
Cooling method Forced cooling using a fan
Operation environmental temperature 0 to +40°c
Fuse 125 VAC, 8A
Temperature protection Fuse Built-In
External dimensions 185(W)×250(H)×333(D)
(except rubber legs)
Weight 10kg

* Due to our standard measuring data.

 

Precautions for use

  • In case of lamp light failure, start up with cooling over 5 minutes.
  • Make sure not to move,swing or give a shock to main housing lighting on which cause lamp burned out.
  • Make sure not lock staright ultraviolet rays irradiated by device and liquid optical fibers.
  • Beause of fear of fire,make sure not to put combustibles on main housing.
  • Make sure not to close the vent because of heating up while light on.
  • Make sure not to use keeping uper door open or removing cover of device preventing shock lamp cooling. Main housing is designed not to supply when upper kept open.
 

Application rod lens (optional)

Rod lenses are available for each application.
(Processing rod end faces to be rectangular or hexagonal according to purpose, and tapering sides.)
Constant irradiation face with a small light intensity loss is possible with these.
• These are optimum for precision adhesion of optical parts (magnetic head, glass lens), LD optical disk pickup, and sealing LCD display plates.