HOME > Products > Super Air Heater > SAH(with a metallic base and metallic case)

ISO9001:2000 certification

ISO9001:2000

Super Air Heater SAH(with a metallic base and metallic case)

Super Air Heater SAH is a air heater that stably supplies high temperature by adjusting voltage and air flow.

 

Major applications

 

Soldering

Soldering
  • Targeted soldering
  • Preheating

Removing burr from molded resin

Removing burr from molded resin
  • Removing burr from molded resin

Thermal caulking

Thermal caulking
  • Thermal caulking

Welding of adhesives

Welding of adhesives
  • By heating just part of the adhesive locally during heat welding, you can process it efficiently.

Shrink film packaging

Shrink film packaging
  • Heat uniformly with the wide nozzle.
  • Set the appropriate heat quantity easily.
 

Features

This super Air heater uses a unique construction for its heating element. The design efficiency for conducting heat from the heating element to the air is 80%, or higher.

 
 

Dimensions

  • AS type
    AS type
  • BS type
    BS type
  • CS type
    CS type
 

Photo

SAH(with a metallic base and metallic case)

 

Specifications

No. Voltage
(V)
Power
(W)
Model a
(mm)
b
(mm)
c
(mm)
d
(mm)
e
(mm)
f(mm)
Hot air outlet
dimensions
g(mm)
Protection tube
outside dia.
1 100 350 1AS 11 10 10 90 - 8.5Φ 13Φ
2 100 350 1BS 11 10 10 90 7 13Φ
3 100 350 1CS 11 10 10 65 33 0.5 x 26 14Φ
4 100 650 1.5AS 11 15 10 100 - 12.5Φ 19Φ
5 100 650 1.5BS 11 15 10 100 2 19Φ
6 100 650 1.5CS 11 15 10 65 37 0.5 x 26 19Φ
7 200 1000 2AS 11 15 10 135 - 12.5Φ 19Φ
8 200 1000 2BS 11 15 10 135 10 19Φ
9 200 1000 2CS 11 15 10 100 45 0.5 x 26 19Φ
 

Precautions for use (make sure to read before use)

  • Make sure to turn on the air supply before turning ON the power.
    (Supplying electricity to the heater without the airflow may cause the heater element to disconnect.)
  • Make sure to turn OFF the power before stopping the air supply.
  • Use with less than rated voltage may shorten the heater life span.
  • Use the heater with an air pressure below 0.5 MPa.
  • When you used the heater near its temperature limit, ensure sufficient airflow is provided.
    (Insufficient airflow rate may shorten the heater life span.)
    • Standard airflow rate to obtain hot air of maximum temperature 800°c with the rated voltage.

E.g.: The airflow rates shown below are the minimum rates. Do not use the heater with lower than the flow rates shown below

 
Heating rating 100V-100W 100V-200W 100V-350W 100V-650W 100V-1000W
Airflow rate 5liters/min 10liters/min 15liters/min 30liters/min 60liters/min
Heating rating 200V-200W 200V-440W 200V-650W 200V-1000W 200V-2000W
Airflow rate 10liters/min 15liters/min 30liters/min 70liters/min 150liters/min

Other heater models,such as ones without sensors and clean heaters,are also available.

GO TOP